SciELO - Scientific Electronic Library Online

 
vol.9 issue1 author indexsubject indexarticles search
Home Pagealphabetic serial listing  

Services on Demand

Article

Indicators

Related links

  • On index processCited by Google
  • On index processSimilars in Google

Share


South African Journal of Child Health

On-line version ISSN 1999-7671
Print version ISSN 1994-3032

Abstract

DE KOCK, S H; OTTO, S F  and  JOUBERT, G. The feasibility of determining the position of an endotracheal tube in neonates by using bedside ultrasonography compared with chest radiographs. S. Afr. j. child health [online]. 2015, vol.9, n.1, pp.3-5. ISSN 1999-7671.

BACKGROUND: Neonates in our neonatal intensive care unit (NICU) receive a large amount of radiation with X-rays (XRs) being done daily, even more often with reintubation, repositioning of endotracheal tubes (ETTs) and confirmation thereof, which has been our NICU policy for many yearsOBJECTIVE: To investigate the feasibility of determining the position of ETTs in neonates by using bedside ultrasonography (BUS), and to compare the results with those obtained from chest XR (CXR) findingsMETHODS: A prospective, cross-sectional study was done on intubated neonates in the NICU at Universitas Academic Hospital, Bloemfontein, to determine the position of ETTs by using BUSRESULTS: Thirty intubated patients included in this study had a median age of 13.5 days and a median weight of 1.6 kg. Ninety-three per cent of ETT placements were considered optimal when visualised by BUS, while 73.3% were considered to be placed optimally when CXR was viewed. When CXR and BUS findings were compared regarding optimal placing, the agreement was poor (κ=0.10; 95% confidence interval -0.2 - 0.4). In four patients, the distance from the aortic arch to the tip of the ETT was outside the expected range of 1.5 - 2.2 cm: in two patients it was <1.5 cm (6.7%) and in the other two >2.25 cm (6.7%). BUS measurements were done mainly in extended head (53.3%) or neutral (36.7%) positionCONCLUSION: Although poor agreement between CXR and BUS findings was obtained, possibly because of handling of patients with secondary shifting of ETTs, BUS was found not to be comparable with CXR, but an alternative feasible method to determine the optimal position of ETTs in the trachea in neonates when using other reference points, with the added advantage of no radiation exposure

        · text in English     · English ( pdf )

 

Creative Commons License All the contents of this journal, except where otherwise noted, is licensed under a Creative Commons Attribution License