SciELO - Scientific Electronic Library Online

 
vol.15 número1Immediate postoperative prosthesis (IPOP) utilisation in septic and tumour amputees in a government hospitalMortality in elderly patients with intertrochanteric fractures: three years' experience índice de autoresíndice de materiabúsqueda de artículos
Home Pagelista alfabética de revistas  

Servicios Personalizados

Articulo

Indicadores

Links relacionados

  • En proceso de indezaciónCitado por Google
  • En proceso de indezaciónSimilares en Google

Compartir


SA Orthopaedic Journal

versión On-line ISSN 2309-8309
versión impresa ISSN 1681-150X

Resumen

BIRKHOLTZ, FF  y  DE LANGE, P. Evaluation of the first experience of intramedullary nail lengthening using PRECICE® in a South African limb lengthening and reconstruction unit. SA orthop. j. [online]. 2016, vol.15, n.1, pp.67-71. ISSN 2309-8309.  http://dx.doi.org/10.17159/2309-8309/2016/v15n1a7.

BACKGROUND: Limb lengthening is performed through distraction osteogenesis after osteotomy and has traditionally been performed using external fixation. The PRECICE® Limb Lengthening System has recently emerged as an alternative method to control distraction. In this study, the first experience of intramedullary nail lengthening using PRECICE®, in a South African limb lengthening and reconstruction unit, was evaluated in terms of the accuracy of distraction and the number of implant-related complications that were reported METHODS: A total of nine patients underwent the limb lengthening procedure in 11 limb segments. Distraction of the nail was initiated by ERC (external remote controller) around 10 days after surgery at a distraction rate of 1 mm/ day. The distraction was monitored every 2 weeks by clinical and radiographic examinations. Ongoing physiotherapy rehabilitation was performed until consolidation was achieved RESULTS: A mean target distraction length of 45.18 mm (15 to 65 mm range) was obtained over an average follow-up period of 266 days, with an accuracy of 103% ± 18%. All the distraction segments united. Two complications were reported that were successfully treated CONCLUSION: Limb lengthening using the PRECICE® nail system was found to have excellent accuracy of distraction, which is reproducible between different segments and indications. Acceptable complication rates were observed in this study

Palabras clave : limb lengthening; PRECICE® nail; intramedullary lengthening; nail lengthening; leg lengthening.

        · texto en Inglés     · Inglés ( pdf )

 

Creative Commons License Todo el contenido de esta revista, excepto dónde está identificado, está bajo una Licencia Creative Commons