Servicios Personalizados
Articulo
Indicadores
Links relacionados
- Citado por Google
- Similares en Google
Compartir
African Vision and Eye Health
versión On-line ISSN 2410-1516
versión impresa ISSN 2413-3183
Resumen
KRUGER, Hester; ALLY, Naseer; NAIDU, Natasha y MAYET, Ismail. A comparison of rebound and applanation tonometry in children with and without primary congenital glaucoma. AVEH [online]. 2024, vol.83, n.1, pp.1-6. ISSN 2410-1516. http://dx.doi.org/10.4102/aveh.v83i1.921.
BACKGROUND: Intraocular pressure (IOP) measurement should be accurate in a paediatric population with primary congenital glaucoma (PCG AIM: This study aims to investigate the difference between the change in IOP measurements using rebound tonometry (RBT) and handheld applanation tonometry (AT) (Perkins applanation tonometer [PAT]) in patients with and without PCG SETTING: Johannesburg, South Africa METHODS: Measurements were taken under anaesthesia, using RBT and AT at 0 min, 5 min and 10 mins after induction and prior to intubation. Corneal pachymetry and corneal diameters were measured RESULTS: Sixty-five children were included, 19 with PCG and 46 without PCG. The mean age (standard deviation [s.d.]) was 3.2 (2.25) years and 4.8 (2.4) years, respectively. The overall mean difference in IOP between RBT and PAT across both PCG and non-PCG groups was found to be 4.92 mmHg (95% confidence interval [CI]: 2.80 - 7.03) p < 0.001, with RBT having higher readings. This difference was greater in the PCG group, with the IOP difference of 9.05 mmHg (95% CI: 2.6 - 15.5) p = 0.004. Mean corneal pachymetry (s.d.) was 585.6 (81.48) µm in the PCG group and 518.31 (39.9) µm in the non-PCG group. Univariate analysis showed that IOP was significantly related to corneal pachymetry, with a 11 mmHg increase in IOP for every 100 μm change in corneal thickness for measurements done with RBT (p < 0.001), compared to 4 mmHg using PAT (p = 0.008 CONCLUSION: Intraocular pressure measurements done with RBT in children with and without PCG were overestimated compared to PAT CONTRIBUTION: This difference was more pronounced in PCG patients. In addition, IOP was significantly related to corneal thickness
Palabras clave : intraocular pressure; applanation tonometry; rebound tonometry; primary congenital glaucoma; paediatric ophthalmology; tonometry; glaucoma; corneal pachymetry.