SciELO - Scientific Electronic Library Online

 
vol.78 número3COVID-19 pandemic and the dental practice índice de autoresíndice de assuntospesquisa de artigos
Home Pagelista alfabética de periódicos  

Serviços Personalizados

Artigo

Indicadores

Links relacionados

  • Em processo de indexaçãoCitado por Google
  • Em processo de indexaçãoSimilares em Google

Compartilhar


South African Dental Journal

versão On-line ISSN 0375-1562
versão impressa ISSN 0011-8516

Resumo

SWAID, AI. The marginal gap and internal fit of monolithic crowns milled with different luting spaces. S. Afr. dent. j. [online]. 2023, vol.78, n.3, pp.120-125. ISSN 0375-1562.

INTRODUCTION: Three of the more promising materials for CAD/CAM restorations are Zirconia (VITA Zahnfabrik, Germany), Enamic (VITA Zahnfabrik, Germany), and the composite material Brilliant Crios (Coltene, Switzerland). Zirconia has been tested for the marginal gap and internal fit; Enamic and Crios have not been tested for marginal gap and internal fit and no studies have tested the effect of different luting spaces METHOD: A standardised crown preparation on a typodont mandibular first molar tooth was scanned and imaged (CEREC CAD/ CAM, Germany). The marginal gap was measured using a Reflex microscope in both two- and three-dimensions. The internal fit was calculated using the properties of the luting agent and the surface area of the preparation RESULTS: The 3D measurements were significantly higher, but only on average 10µm higher. The marginal gaps of the crowns milled with a 200µm luting space were significantly smaller than for those milled with a 100µm luting space. The smallest mean gap was recorded by Enamic at 31.7µm followed by Crios at 32.5µm, and Zirconia at 33.1µm. All of these measurements are well within acceptable clinical limits CONCLUSIONS: All crowns milled, regardless of the luting space used, provided excellent marginal and internal fit, well within clinically acceptable parameters. The 3D measurements are more clinically relevant than 2D measurements. The smallest marginal gaps were found in the crowns milled with a 200pm luting space. However, this can present problems with non-axial seating and so it may be advisable to use the 100pm luting space parameter

Palavras-chave : Marginal gap; Internal fit; CAD/CAM full coverage crowns.

        · texto em Inglês     · Inglês ( pdf )

 

Creative Commons License Todo o conteúdo deste periódico, exceto onde está identificado, está licenciado sob uma Licença Creative Commons