SciELO - Scientific Electronic Library Online

 
vol.28 número1American College of Radiology Thyroid Imaging Reporting and Data System standardises reporting of thyroid ultrasoundsIncidental amniocele in a case of antepartum haemorrhage índice de autoresíndice de assuntospesquisa de artigos
Home Pagelista alfabética de periódicos  

Serviços Personalizados

Artigo

Indicadores

Links relacionados

  • Em processo de indexaçãoCitado por Google
  • Em processo de indexaçãoSimilares em Google

Compartilhar


SA Journal of Radiology

versão On-line ISSN 2078-6778
versão impressa ISSN 1027-202X

Resumo

KOZłOWSKI, Filip M.; VAN REENEN, Christoffel J.  e  TRAUERNICHT, Christoph J.. Establishment of local diagnostic reference levels for CT colonography at a tertiary hospital. S. Afr. J. radiol. (Online) [online]. 2024, vol.28, n.1, pp.1-5. ISSN 2078-6778.  http://dx.doi.org/10.4102/sajr.v28i1.2809.

BACKGROUND: Diagnostic reference levels (DRLs) are an important metric in identifying abnormally high radiation doses in diagnostic examinations. National DRLs for CT colonography do not currently exist in South Africa, but there are efforts to collect data for a national DRL project. OBJECTIVES: This study investigated radiation doses for CT colonography in adult patients at a large tertiary hospital in South Africa with the aim of setting local DRLs. METHOD: Patient data from two CT scanners (Philips Ingenuity and Siemens Somatom go.Top) in the period March 2020 - March 2023 were obtained from the hospital's picture archiving and communication system (PACS) (n = 115). Analysis involved determining the median computed tomography dose index-volume (CTDIvol) and dose-length product (DLP) values. The findings were compared with DRLs established internationally. RESULTS: Ingenuity median CTDIvol was 20 mGy and DLP was 2169 mGy*cm; Somatom median CTDIvol was 6 mGy and DLP was 557 mGy*cm. Ingenuity exceeded the United Kingdom's (UK) recommended DRLs by 82% and 214%, respectively. Somatom median CTDIvol and DLP were 45% and 19% lower than UK NDRLs. CONCLUSION: Somatom's tin filter and other dose reduction features provided significant dose reduction. These data were used to set DRLs for CT colonography at the hospital; CTDIvol: 6 mGy and DLP: 557 mGy*cm. CONTRIBUTION: In addition to informing radiation protection practices at the level of the institution, the established local DRLs contribute towards implementing regional and national DRLs.

Palavras-chave : computed tomography; CT; colonography; dose optimisation; diagnostic reference level; computed tomography dose index-volume; dose-length product.

        · texto em Inglês     · Inglês ( pdf )

 

Creative Commons License Todo o conteúdo deste periódico, exceto onde está identificado, está licenciado sob uma Licença Creative Commons